Need to know how to operate a climate master air conditioning and heating system. D from inside house connect 3 pump wire leads to 3 control box wire leads.
714 Select Stat Swamp Cooler Wiring Diagram Wiring Library
Bonaire evaporative wiring diagram. Failure to do so will void all guarantees beyond statutory and legal requirements. Here is how to wire up a 120 volt swamp cooler switch controller. Drill 2x18 32mm holes and insert screws into unit as per diagram and repeat for window frame with appropriate screws. Httpsamznto2kx6lud click here for a complete write up on wiring a swamp cooler. Page 1 owners manual bonaire evaporative cooler please keep this important manual in a safe place. Discharge duct design critical to the air performance of the product.
Wiring a evaporative swamp cooler switch duration. Color of ground wire from control box is yellow with a green stripe. Underside of the fan housing see diagram below. See wiring diagram below make ground connections as shown note. Ensure that the cooler is now fixed rigidly to the house structure e in fill panel to fit in the gap and seal any gaps top edge of rear filter panel. Secure connected wire leads using wire nuts and electrical tape.
It is the owners responsibility to ensure that regular maintenance is carried out on this air conditioning product. Where flexible ductwork is used all bends must have a minimum radius of 15 times the diameter. Evaporative coolers also called swamp coolers and swampers are cheaper to purchase and run than air conditioner units but only function well in hot dry climates. The diagram to the left is a very typical rambler style one level home with a basement mechanical room. The motor in a swamp cooler turns a blower which moves air in from outside the cooler through evaporative pads and out through a vent or ducting into the living area. Amazon affiliate link to swamp cooler switch.
Your home may be configured differently but you should still be able to adapt the basic wiring and water line configuration into your home. The water level should be 65mm to 70mm from the overflow window on the bonaire aquamiser step 2 turn the unit on and set the pre cool function. All duct designs and airflows must be calculated by a qualified air conditioning consultant or contractor in accordance with normal good ducting practices. Operation manuals including instructions on how to use your remote control for selected climate master air conditioning and heating units can be found below. Everything you wanted to know about restoring or replacing your swamp cooler. Installation instructions 40 connections 44 aquamiser wiring diagram control box bonaire eac page 19.
Commissioning step 1 turn the water on to unit and allow unit to fill. Risk of fire electric shock or injury to persons.