Main power wire from electrical panel to outdoor unit. 4 follow all local building codes and nec national electrical code regulations.
Gree Split Air Conditioner Wiring Diagram Gree Air
Gree mini split wiring diagram. Also look for connecting wire that is rated for sun exposure and ul listed. View and download gree gwh09kf a3dnb1a installation manual online. 1 u match air conditioners service manual ä t1r410a50hz å gree electric appliances inc. 3 use table above to size over current protection. 2 main power is supplied to the outdoor unit. Wiring mini split dc control lines.
Electrical ac wiring will need to be bought separately from diy mini split kits and is not included. Mounting bracket diagrams and dimensions 09k and 12k unit 18k unit 24k unit 30k and 36k unit right rear piping hole left. Page 1 g r e e a i r c o n d i t i o n e r s thank you for choosing gree air conditioner for correct operation please read this owners manual carefully before operating the unit and keep. Gree neo ductless heat pump for your customer. Ductless inverter heat pump. 2 safety precautions.
The ground be con be sure to pull out the power plug select the most. Electric wiring gree split air conditioner owners manual page 23acsons sarl. Dc control lines are included in most any good diy mini split install package. There is usually 3 5 dc control lines which are easy to wire up. Connect all wiring tightly. Improper connections inad equate grounding can cause accidental injury or death.
Loose wiring may cause over heating at connection points and a possible fire hazard. 5 allowable voltage drop. Following the same wire colors and terminal references from the indoor unit. Carefully refer to the wiring diagram and these instructions when wiring. Main power wire from electrical panel to outdoor unitawg based on 240vac single phase 100 ft. The dc control wires go between the inside and outside units.
Operation and maintenance notices for operation operation and maintenance notices for operation earth. Mini split heat pump seer 16 12000 btu 24 pages. Black wiring diagram brown 18k and 24k btuh grnyel black white interconnecting wires grnyel main power wires 5. 1 system must be on a single dedicated circuit. Power and wiring 16 vacuum testing 19 start up 21 troubleshooting 22. Ground the unit local electrical codes.
When shopping for connecting wire be sure to get quality wire that is the proper gauge. Refrigerant pipe lengths unit size refrigerant factory system max pipe length wout additional btuh type charge ozkg adding refrig ftm charge ozft gm 18000 r 410a 565 16 33 10 02 20. Mini split systems have specific wire gauge thickness requirements and the difference between the right and wrong electrical wire can be dangerous.