Notifier fcm 1 rel wiring diagram. Current rating maximum voltage load description application. A wiring diagram is a simplified conventional pictorial representation of an electric circuit. Fcm 1a installation document i56 1169. Mounting the frm 1 mounts directly to 4 square electrical boxes see fig ure 2a. 16112018 16112018 3 comments on notifier fcm 1 wiring diagram. Notifier nfse manual online.
Maximum slc current draw. Compatible notifier system control panels only list available from notifier. The fcm 1 rel releasing control module uses a redundant protocol. The module must be armed with a pair of signals in order to activate. Connecting a releasing device to a fcm 1 module connecting an. Notifier fcm 1 wiring diagram.
If using the on board nacs see circuit requirements for section 474 connecting a releasing device to the control panel on page 44. 65 ma led on temperature range. Variety of notifier fcm 1 wiring diagram. For installation instructions see the following documents. Connecting a releasing device to the fcm 1 rel. Dn 6724 040504 page 1 of 4 fcm 1 module see wiring diagram fig.
4675 h x 4275 w x 14 d mounts to a 4 square by 218 deep box specifications for frm 1. The fcm 1 rel module must be programmed with the correct releasing type code listed in the nfs 320ec programming manual. Any number of ul listed contact closure devices may be used. Notifier nfs manual online. All wiring must conform to applicable local codes ordi. Maximum slc current draw.
Fmm 1 connect modules to listed compatible notifier control panels only. Install contact closure devices per manufacturers installation instructions. Ing power limited and non power limited wiring in the same junction box as fcm 1a. All wiring shown is supervised and power limited. Mounting the fcm 1 mounts directly to 4 square electrical boxes see figure 2a. Compatible notifier system control panel list available from noti fier.
Frm 1a installation document i56 3502. All wiring must conform to applicable local codes ordi. Surface mounted electrical boxes smb500 are available. 5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit. The box must have a minimum depth of 218. Page 5 wiring diagrams this page.
15 to 32 vdc. 15 to 32 vdc. If no confirmation is received the module will automatically reset. Notifier slc wiring manual document 51253. Releasing applications c limited energy cable cannot be used to wire a. The box must have a minimum depth of 21 8.
It will then enter a 3 second window awaiting a pair of confirmation signals. 32f to 120f 0c to 49c dimensions.