Remove the violet wire from indoor live. Half fill the condensate collection tray with clean tap water the pump will start on low power.
How To Install A Microblue And Fascia Kit To A Carrier Mini
Refco gobi 2 wiring diagram. 319 x 288 x 110 lxwxh part no. Benefits of the new refco pump. Remove the gobi cover. Allow the gobi to remove the. Disconnect all power supplies. Change alarm relay to fail safe operation.
Continue to add water until the sensor is fully submerged the pump will switch to full power and the alarm contacts will open. The majority of mini split evaporator installations do not require a condensate pump because the evaporator pan is drained by gravityrefco universal condensate pumphelp wiring gobi condensate pump 0 thoughts on gobi 2 condensate pump wiring diagram. 2 0 gobi ii combi at full power 60 50 40 30 20 10 0 ve rt ical li ft head pressure m. Easy to use 2 color led indicator lights ensure proper installation and offer diagnostic service assistance. Change alarm relay to fail safe operation. The all new gobi ii condensate pump has been completely redesigned retaining all the good features you like and upgrading everything else.
The gobi ii uses a standard 120240vac. Typical data vrf condenser unit outdoor 100 240vac neutral. Identifies pc board or wiring faults on data link circuits led indicators show correct operation dimension. Connect the orange wire to indoor live. The gobi ii has a massive flow range allowing its use from 6000 btuh 175kw up to 120000 btuh 35 kw. Remove air handler cover gobi cover and condensate collection tray.
It may be noisy whilst air is purged from the system. Wire from indoor live. To use fail safe operation. Connect the orange wire to indoor live. Telefon 41 41 919 72 82 industriestrasse 11 telefax 41 41 919 72 83 ch 6285 hitzkirch switzerland info at refcoch wwwrefcoch installation operation and maintenance guide for installation and service engineers gobi condensate pump important. Installation instructions video gobi iisep 16 help wiring gobi condensate pump i am trying to wire a gobi pump to a mitsubishi minisplit head and the head has an s1 s2 and s3.
Allow the gobi to remove the water from the collection tray the pump will stop and the alarm contacts will close. Read this booklet before installation of this product. 5060 hz auto sensing universal power input and will operate with water temperatures from 41 77f 5 25c and ambient air temperatures from 375 104f 3 40c. The all new gobi ii condensate pump has been completely redesigned retaining all the good download. Coil cleaning do not allow the pump to collect or operate with cleaning chemicals in the system. Re fit the gobi cover.